Gabion mattresses are rectangular containers made of hexagonal woven steel wire mesh laced together and filled with stones or crushed rock, also known as Reno Mattresses.

Goto Zishen to know more.

Gabion Mattresses are flatter and wider gabions with lower profile, ideal for preventing soil erosion and protecting against scour and undercutting. Gabion Basket Mattresses have been used for channel linings, river training, soil retention, slope stabilization, and other construction engineering applications throughout the world for over 100 years.

Mattress gabions are commonly made from heavy galvanized or PVC-coated wire for corrosion protection.

Gabion mattress mesh:

Triple twisted hexagonal mesh;
Double twisted hexagonal mesh.

Triple-twisted hexagonal mesh material is made with annealed mild steel wire heavily zinc coated of the following wire sizes: 

Type of Wire

Min. Diameter

Selvage (perimeter) wire

3.60 mm

Mesh wire

2.82 mm

Tying and connecting wire

2.23 mm

 

Double twisted mesh gabion mattresses for river bank trench lining

Wires for gabions and mattresses can be polyester coated. The wires are resistant to chemical attack in the pH range 2 to 9, be resistant to attack by bacteria, and not be attractive to vermin.  Gabion mattress wire is stable over a temperature range of -60&#; to 100&#; and be resistant to degradation by ultraviolet radiation such that strength loss due to 10 years exposure to sunlight shall not exceed 20%.

The mesh is securely tied to salvage wires to form rectangular panels, the mesh panelsl are securely wired together to form the completed gabion baskets. The ties and connections for each gabion basket comprise not less than 8% of its total weight, and the fabrication shall be all to the satisfaction of the Engineer.

Gabions are made to the sizes specified by customers according to gabion project requirement. Gabion mattresses are made to sizes per details of trenches for sewer pipes and as per specifications. Each gabion mattress or compartment of a gabion mattress shall be provided with at least 4 cross- connecting wires.

Gabion Mattress is a double twisted hexagonal woven galvanized steel wire mesh basket fabricated in a rectangular mattress shape. The compartment or cells of the mattress are of equal size and dimension and are formed by internal diaphragms being placed within the basket providing even distribution of the stone fill throughout the mattress even after structural movement. Even distribution of the stone fill ensures that the reno mattress maintains intimate contact with the foundation soil.

Gabion Mattresses offer many advantages over other types of construction materials.

Advantages offered by double twisted mesh gabion mattresses:

Flexibility, durability, strength, permeability, ecology, reliability, longevity, low cost, and an aesthetic appearance.

Flexibility - the most important advantage of using gabion mattresses
Gabion mattress has a flexibility both for the individual unit and the overall gabion structure. The Double Twisted Hexagonal Mesh construction of the units permits it to tolerate differential settlement without failure. This property is especially important when a structure is on unstable soil conditions or in areas where scour from wave action or currents can undermine the toe of the structure and cause structural settlement.

Durability - achieved by high strength material and structural integrity
Material: Gabion Mattresses are built from high strength double twisted hexagonal mesh and connected together to create a monolithic mass structure capable of undergoing structural movement without any loss of structural integrity creating a highly durable structure.

Strength - to withstand forces generated by water and earth masses - Strength value in ASTM A975-97
The strength of gabion mattresses is achieved in several aspects:
breaking strength;
the mesh wire tensile strength;
Pull apart resistance strength of the mesh;
Corrosion resistance of the mesh.

Permeability - Free Draining Structure
The porous structure permits an active air circulation through the wire netting and soil is deposited and plant growth invades the structure, transpiration further assist in removing moisture from the soil being protected.

Mattress geometry and material properties

Length

Width

Height

6 metre

2 metre

0.3 metre

Galvanised and PVC coated Gabion Mattress of Triple Twisted Hexagonal Mesh

Project for Slope Protection /Scour Protection

The gabion mattress manufacturer is ISO certified and the published technical data and values must be verified by Third Party Quality Assurance according to DIN .

Gabion Mattress 375mm thick for slope scour protection including filter fabric or concrete slope protection inclusive of necessary design where directed by Engineer.

Gabion Mattresses for Flood Protection Embankment

Triple Twisted Hexagonal Mesh Gabion Mattresses are mostly used in projects of Flood Embankment and intake works. Gabions types are boxes and mattresses. Aerct supplies quality gabions system for flood protection, with detailed requirements for the gabion wire, mesh fabric, filter fabric, stones and construction of gabions work as following.


The correct joining of separate gabion mattresses with triple twist every two meshes


Hexagonal Triple Twisted Wire Mesh Details


Gabion Mattresses to be filled with stones of 75 to 200mm

 

Technical Requirements of Gabion Mattresses

1. Wire Fabric for Gabions

All wire used in the fabrication of gabions (including selvage wire and lacing wire) and in the wiring operating during construction (including tie wire) shall be annealed mild steel wire, having an average strength of 38-50 kg/mm2. Wire thicknesses are as given below.

Gabion type Wire Size
(mm) Mesh Size
(mm) Box gabions 2.7 80*100 Mattresses 2.2 60*80 Lacing Wire 2.2 150 Selvedge wire(boxes) 3.4   Selvedge wire(mattress) 2.7 200

All wire shall be galvanized meeting international standard of "Galvanized Coatings on Wire".
The minimum weight of the zinc coating shall be according to the figures shown in the table below:

Nominal Diameter of wire
(mm) Minimum weight of
coating
(gr/mm2) 2.2 240 2.7 260 3.4 275

The adhesion of the zinc coating to the wire should be such that, when the wire is wrapped six turns round a mandrel of 4 times the diameter of the wire, it does not flake or crack to such an extent that any flakes of zinc can be removed by rubbing with the bare fingers.

If you want to learn more, please visit our website vinyl coated welded wire fencing.

Wire mesh fabric shall be hexagonal triple twist mesh. The tightness of the twisted joints shall be such that a force of not less than 1.7kN is required to pull on one wire to separate it from the other wire provided that each wire is prevented from turning and the whole process is done in one plane. Ultimate failure load in the direction of the weave will be about 43 kN/metre length. Longitudinal elongation of mesh will not exceed 10%.

Joining of Gabion Boxes and Mattresses and edge treatment:
The mesh cages shall be subdivided into cells by wire-mesh diaphragms with a maximum dimension of 1.0 m for boxes, and 2 x 0.6 m for mattresses.

All edges of gabions, diaphragms and end panels shall be selvedged in such a way as to prevent raveling of the mesh and to develop the full strength of the mesh. The amount of lacing wire should be approximately 5% of the gabion weight.

The gabion mesh shall be cut, folded and wired together to form joints, angles, curves or slopes which are not possible to obtain in the structures with the standard rectangular gabions, the mesh must be cleanly cut, and the surplus mesh cut completely out, or folded back or on to, and neatly wired to an adjacent gabion face. The cut edges of the mesh shall be securely laced together with binding wire.

2. Filter Fabric for Gabion Mattresses Embankment Works

Gabions and mattresses should be laid on a filter fabric.
The filter fabric shall be of a non-woven melted fabric consisting of a mixture of polypropylene and polythene or other similar materials. The fabric shall be resistant to ultra violet rays and sunlight.
Where overlapping of fabric is required, the overlap shall not be less than 500 mm and shall be sewn with a lock type stitch in such a manner that it produce a joint as durable as the fabric.
The grade of fabric shall weigh not less than 350 gr/m2 and have a thickness of 0.5 mm.
Tensile strength shall be not less than 2kN/m. Permeability (ViH50) shall be not less than 60l/s*m2.
Storage and handling of the fabric in no case shall be the geotextile be exposed to direct sunlight, ultra violet rays, temperature greater than 60o C, mud, dirt, dust and debris, to the extent that its strength, toughness or permeability characteristics are diminished.
In some cases it will be necessary to cut back the fine sand layer in the bank to a depth of 20 cm and replace with as-dug river gravel.

3. Stones for Gabions

Stone used for gabions and gabion mattresses shall be clean, natural, hard and durable with a minimum density of 2,650 kg/m3. Stone shall be well graded within the following limits, but at least 85% by weight of the rock fragments shall have a size equal to or larger than 100 mm. No rock shall be capable of passing through the mesh.

Gabion type Minimum
dimension
(mm) Maximum
dimension
(mm) Box gabions 100 250 170 mm mattress 75 120 230 mm mattress 75 150 300 mm mattress 75 200 500 mm mattress 75 200

Stone shall preferably be rounded rather than angular.

4. Method of Construction

a. Gabions and gabion mattresses shall have internal diaphragms of the same mesh as the enclosing fabric.

b. Gabion shall be installed in a workmanlike manner, the gabion shall be placed on smooth surface, final line and grade shall be approved by engineer.

c. Rock pieces shall be generally uniformly graded from 75mm to 200mm for mattresses, 100mm to 200mm for gabion box.

Galvanized / Galfan Gabion Mattress 0.17m, 0.23m, 0.30m

Galvanized Wire Gabion Mattress and Mattress Baskets

Gabions mattresses is ideal products to protect coastline, and the HDPE coated woven gabions mattresses is a good solution to protect where there is a wave and a high level of acid in industrial waste.


Gabion mattress mesh workshop.

Gabion mattress mesh workshop.


Heavy Galvanized woven gabion mattress for soil erosion protection.

Heavy Galvanized woven gabion mattress for soil erosion protection.

Heavily galvanized wire mattress baskets 6 × 2 × 0.3 m

  • Mesh wire = 2.7 mm.
  • Mesh size 8 × 10 cm.

Gabion mattresses

  • Specification: hot dip heavy coated galvanize (Zinc should be 240 to 270 g/m2).
  • Selvedge wire: 3.40 mm.
  • Mesh wire: 2.70 mm.
  • Lacing wire: 2.2 mm (5% of total weight with each mattresses).
  • Mesh size: 60 × 80 mm.
  • Mattresses size:
    • 5 × 2 × .30.
    • 4 × 2 × .30.
    • 3 × 2 × .30.
    • 6 × 2 × .17.
    • 5 × 2 × .17.
    • 4 × 2 × .17.
    • 3 × 2 × .17.

Gabion mattress (60 × 80 mm mesh, galfan coated):

  • 6 meters. × 2 meter. × 0.17 meter.
  • 6 meters. × 2 meter. × 0.22 meter.
  • 6 meters. × 2 meter. × 0.30 meter.
  • 6 meter. × 1 meter. × 0.17 meter.
  • 5 meter. × 1 meter. × 0.17 meter.
  • 4 meter. × 1 meter. × 0.17 meter.
  • 3 meter. × 1 meter. × 0.17 meter.
  • 2 meter. × 1 meter. × 0.30 meter.
  • 4 m (length) × 2 m (width) × 0.30 m (height).
  • 4 m (length) × 2 m (width) × 0.23 m (height).
  • 3 m (length) × 2 m (width) × 0.30 m (height).
  • 3 m (length) × 2 m (width) × 0.23 m (height).
  • 2 m (length) × 1 m (width) × 0.23 m (height)

Mattress with 6 cells, total dimensions 6.0 × 2.0 × 0.23 m

  • Wire diameter: 2 mm.
  • Mesh size: 60 × 80 mm.

Stainless steel gabions

  • Size: 600 × 600 × 300 mm.
  • Opening: 50 mm.
  • Thickness: 4 mm.

Mattremesh system for reinforced soil embankments with slope angle of up to 70. Gabions with double twisted mesh measure 10 × 12 cm holes with 2.7 mm Galfan.

Mattress gabion (60 × 80 mm mesh, galfan coated):

  • 6m × 2 × 0.17.
  • 6m × 1 × 0.17.
  • 5m × 1 × 0.17.
  • 4m × 1 × 0.17.
  • 3m × 1 × 0.17.

PVC reno mattress

  • It's wire of double spring, material is plating steel in PVC shell.
  • Size: 3 × 2 × 0.17 m.

Gabions and mattresses

  • 3 mm core dia. chain link galvanised steel gabion units, mesh openings 80 × 110 mm.
  • Gabion size 900 high × 900 wide × mm long.
  • Reno mattress size 300 high × wide × mm long.

Mattresses gabion

  • 230 mm thick.
  • 4.5 m wide 138 m.
  • 3 m wide 24 m.
  • 1.5 m wide 170 m.
  • 6 m × 2 m 82 no.

Reno mattress (gabion box)
Reno mattresses (6 × 2 × 0.30), using hexagonal woven double twisted type 60 mm mesh to ASTM A975-97(), with 2.2 mesh wire, and 2.7 selvedged wire, galvanized to ASTM A975-97() and coated with extruded 0.5mm grey PVC layer to ASTM A975-97(), complete with partitions @ 1.0 centres. - Quantity = 150,000.00 Cum.

Double twist woven hexagonal wire mesh mattresses 6 m × 2 m × 0.23 m

  • Manufactured from 60 mm × 80 mm × 2.00 mm wire diameter.
  • Wire with galfan coated and plastic coated gray to 3.00 mm overall, in accordance with international industry standard.

Inquiry for Our Product